Files
2026-05-21 14:27:53 +00:00

1.3 KiB

Error Codes

HWLAB uses JSON-RPC standard errors plus a reserved HWLAB server-error range.

Code Name Meaning
-32700 parse_error Invalid JSON payload.
-32600 invalid_request Invalid JSON-RPC envelope.
-32601 method_not_found Method is unknown to the target service.
-32602 invalid_params Method parameters failed validation.
-32603 internal_error Unexpected service failure.
-32000 hwlab_unknown Unclassified HWLAB runtime error.
-32010 project_not_found Project ID is not known or not visible.
-32011 session_not_found Gateway, agent, or worker session is missing.
-32020 capability_unavailable Requested hardware capability is unavailable.
-32021 resource_locked Box resource is already reserved or running.
-32022 wiring_invalid Wiring config violates topology constraints.
-32023 operation_rejected Hardware operation cannot be accepted.
-32030 evidence_missing Required evidence record was not produced.
-32040 audit_required A mutating action was attempted without audit metadata.

Error responses must include error.message. error.data should carry stable machine-readable fields such as projectId, sessionId, resourceId, or operationId when available.